PRODUCT

High Level & Overfill Alarm System

Acoustic Wave Type / Float Type

Cargo Tank High Level & Overfill Alarm System

  • The CMS is a fully autonomous solution, which meets the standards for protection against accidental cargo tank overflow.
  • ts primary advantage is use of the Honeywell Lidec L91/92 (single/dual-probe) or the Sunil Float Type as two independent level alarms

LIDEC & FLOAT Type

  • LIDEC
    Liquid Level Switch designed for maritime applications
    : an effective solution for detecting the level of liquds. Equipped with one or two modular probes, it is a fully static device using propagation of a surface wave which avoids any mechanical moving parts.
    The detector is insensitive to vibration, shock and electrical disturbances, and is SIL2 comploant according to IEC61508
  • FLOAT Type
    High level alarm sensor consists of magnetic float and reed switch built in guide pipe. When the liquid level reaches a set point, the reed switch in the alarm sensor is actuated by magnetic float

Testnical Specification

  • Detection Units :
    Reed switch with magnetic float / Accustic Wave Type
  • Detecting Accuracy : ±3mm
  • Switch Contact Rating : DC24V / DC24V, Outout : 6mA
  • Working Temp : -196~100℃ / -40~200℃
  • Specific Gravity : 0.42 Above
  • Material
    - Housing : SUS304/316
    - Flange : SUS304/316
    - Guide pipe : SUS304/316
    - Float : SUS316 , Titanium
  • Anti-Explosion Structure : Intrinsically safe type
  • Allowable Pressure : 10 Bar
  • Connection Size
    Installation - JIS SK-100A FF / ANSI #150 4" / OTHER SIZE
    125A FF With Chamber
    Conduit - JIS SK-32A / 40A / PF3/4" / PF1"

about company Sunil Instrument co., ltd

34, Sinhisandan 3-ro 88beon-gil, Gangseo-gu, Busan, Korea

  • +82 51 831-1994
  • +82 51 831-2994
  • suniltech@suniltech.co.kr