PRODUCT

Cargo Monitoring System

Radar Beam Type (EM540)

Introductions

The EM540 Radar is an 8 inch smart radar level solution specifically designed for tanker level measurements involving chemicals, hydrocarbons, bitumen, etc. It transmits all data(level, inert gas pressure, temperature) to the central monitoring system. The proprietary flat antenna “Planar” reduces product build up and makes the cleaning procedure quick and easy

Technical Data

  • Accuracy : Instrument: ±3 mm Operating : ±5 mm
  • Resolution : 1mm
  • Range : 0.6 to 42 m
  • Maximum pressure :1bar
  • Operating temperature : -40°C to +70°C
  • Product temperature : -40°C to +250°C
  • Storage temperature : -40°C to +85°C
  • Antenna aperture angle : 13°(FMCW 10GHz)
  • Protocol : EMS
  • Protection clase : IP66/67
  • Intrinsic safety approval : IECEx, ATEX.Il 1 (1) G Ex ia (ia Ga) llB or llC T4 Ga IP66/67

* with special mounting features

Special Mounting Feature

  • Automatic radar self-test during power up
  • Material: Housing stainless steel 316L
  • Antenna FEP protection
  • 3 PT100 temperature inputs
  • 3 Analog inputs
  • Automatic antenna fouling detection

Safety Unit (TA3840S)

Technical Data

  • Intrinsically safe : 11 (1) G (EEx ia) IIB or IIC
  • 1/O port : RS232 on front face of power supply board
  • Transmitter connection number : up to 16
  • Terminal capacity : 2.5 mm2
  • Operating temperature : 5 to +70°C
  • Power Supply : 115 or 230Vac / 50-60Hz
  • Consumption : 100 VA max. per rack

Special Mounting Feature

  • Dedicated Protocol : for EMS
  • Dimensions : 19" 3U rack
  • 2 x front led : for power supply indication
  • 2 x 2 front led : for communication (Rx,Tx) indication

Communication Unit (TA3840C)

Technical Data

  • Power supply : 24Vdc
  • Max . radar capacity : 64
  • Max. inputs other than radar : 96
  • Multifunction board :
    - 8 x 4-20mA,
    - 16 x binary input
    - 24 x binary output.
  • Analog board : 48 x 4-20mA
  • External digital sensors/systems : EMS protocol
  • Communication ports :
    - 3 x RS232, RS485 or RS422
    - 1 x RS 232 or RS485
    - 1 x RS485 (digital sensors/systems input)
  • Monitoring : 2 x alarm thresholds per channel
  • Operating temperature : 0°C to +70°C
  • Protocol : Modbus - RTU

Special Mounting Feature

  • Rack size : 19' 3U (483 x 132 x 185mm)
  • 3 x relay output :
    (COM, NO, NC) for supply fault, data alarm and system faults. Remote display with full indication. Dedicated menus for system maintenance and Commissioning. Combined board can be used when there is few 4-20mA inputs such as inclinometer, draft

Communication Unit (TA3840C)

Technical Data

PRESSURE 3-wire absolute transmitter

  • Scale : 800 to 2000 mbare
  • Accuracy : ±0.3% of measured scale
  • Output : 0.5 to 2.5 Vdc
  • Allowable overpressure : 4000 mbar (Abs)
  • Power supply : 5 Vdc

TEMPERATUR

  • Temperature sensors : 3-wires 1000 at 0°C
  • Accuracy : IEC 751 class B
  • Range : -46°C to +250°C

GENERAL

  • Intrinsically safe : EEx ia IIC T6
  • Protection class : IEC 751 class B
  • Storage temperature : -55°C to +85°C
  • Ambient operating temperature : -40°C to +70 °C

Special Mounting Feature

  • Materials
    sensors, sheathed cable and head: SS316L The sensor assembly inside the housing can be 2 disconnected to facilitate the cleaning of the pressure tap This transmitter can only be connected to radarse
  • Optional
    Cable protection by flexible hose BV2 or BV3 according to cable diameter
  • Codes
    - T901-P11A: 1 sensors
    - T901-P21A: 2 sensors

about company Sunil Instrument co., ltd

34, Sinhisandan 3-ro 88beon-gil, Gangseo-gu, Busan, Korea

  • +82 51 831-1994
  • +82 51 831-2994
  • suniltech@suniltech.co.kr